CLJGT - GLOSS GREEN 14062

  • MSDS: CLJGT
  • Manufacturer: SHERWIN WILLIAMS CO THE
  • Product Name: GLOSS GREEN 14062
  • National Stock Number: 8010-01-344-6699
Product Identification

Product ID:GLOSS GREEN 14062
MSDS Date:04/10/2000
FSC:8010
NIIN:01-344-6699
Status Code:A
MSDS Number: CLJGT

Responsible Party
SHERWIN-WILLIAMS CO THE
101 PROSPECT AVE NW
CLEVELAND, OH 44115-1042
US

Emergency Phone: 216-566-2917

Info Phone: 216-566-2902/216-566-2917

Preparer: HENRY SIMMONS

Cage: 54636

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

MINERAL SPIRITS

CAS: 64742-88-7

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM


TOLUENE

CAS: 108-88-3

RTECS: XS5250000

OSHA PEL see Table Z-2

ACGIH TLV: 188 MG/M3;50 PPM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


LIGHT AROMATIC HYDROCARBONS

CAS: 64742-95-6

RTECS: WF3400000


1,3,5-TRIMETHYLBENZENE

CAS: 108-67-8

RTECS: OX6825000

OSHA PEL 25 PPM

ACGIH TLV: 25 PPM


1,2,4-TRIMETHYLBENZENE

CAS: 95-63-6

RTECS: DC3325000

OSHA PEL 25 PPM

ACGIH TLV: 25 PPM


2-ETHYLHEXANOIC ACID COBALT(2+) SALT

CAS: 136-52-7


CALCIUM CARBONATE

CAS: 471-34-1

RTECS: FF9335000

OSHA PEL 15 MG/M3

ACGIH TLV: 10 MG/M3

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:UNKNOWN IARC:YES
Health Hazards Acute and Chronic:COBALT AND COBALT COMPOUNDS ARE
CLASSIFIEDS BY IARC AS POSSIBLY CARCINOGENIC TO HUMANS (GROUP 2B)
BASED ON EXPERIMENTAL ANIMAL DATA, HOWEVER, THERE IS INADEQUATE
EVIDENCE IN HUMANS FOR ITS CARCINOGENI CITY. PROLONGED
OVEREXPOSURE TO SOLVENT INGREDIENTS IN SECTION II MAY CAUSE ADVERSE
EFFECTS TO THE LIVER, URINARY, BLOOD FORMING, CARDIOVASCULAR AND
REPRODUCTIVE SYSTEMS. REPORTS HAVE ASSOCIATED RE PEATED AND
PROLONGED OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NERVOUS
SYSTEM DAMAGE.
Effects of Overexposure:HEADACHE, DIZZINESS, NAUSEA, AND LOSS OF
COORDINATION ARE INDICATIONS OF EXCESSIVE EXPOSURE TO VAPORS OR
SPRAY MISTS. REDNESS AND ITCHING OR BURNING SENSATION MAY INDICATE
EYE OR EXCESSIVE SKIN EXPOS URE.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

First Aid

First Aid:IF INHALED: IF AFFECTED, REMOVE FORM EXPOSURE, RESTORE
BREATHING. KEEP WARM AND QUIET. IF ON SKIN; WASH AFFECTED AREA
THOROUGHLY WITH SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND
LAUNDER BEFORE R EUSE. IF ON EYES: FLUSH EYES WITH LARGE AMOUNTS
OF WATER FOR 15 MINUTES. GET MEDICAL ATTENTION. IF SWALLOWED: GET
MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:=37.8C, 100.F
Lower Limits:0.7
Upper Limits:13.1
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT INCLUDING
SELF-CONTAINED BREATHING APPARATUS SHOULD BE USED. WATER SPRAY MAY
BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE PREFERABLE. WATER
MAY BE USED TO COOL CLOSED CO NTAINERS TO PREVENT PRESSURE BUILD-UP
AND POSSIBLE AUTOIGNITION WHEN EXPOSED TO EXTREME HEAT.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
FROM HEAT, ELECTRICAL EQUIPMENT, SPARKS, AND OPEN FLAME. CLOSED
CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT. APPLICATION TO
HOT SURFACES REQUIRES SPECIA L PRECAUTIONS. DURING EMERGENCY
CONDITIONS OVEREXPOSURE TO DECOMPOSITION PRODUCTS MAY CAUSE A
HEALTH HAZARD.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.

Handling

Handling and Storage Precautions:CONTENTS ARE COMBUSTIBLE. KEEP AWAY
FROM HEAT AND OPEN FLAME. CONSULT NFPA CODE. USE APPROVED BONDING
AND GROUNDING PROCEDURES. KEEP CONTAINER CLOSED WHEN NOT IN USE.
TRANSFER ONLY TO APPROVED CONTAI NERS WITH COMPLETE AND APPROPRIATE
LABELING. DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND
INHALING THE CONTENTS CAN BE HARMFUL OR FATAL.

Exposure Controls

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
APPLICABLE LIMITS BY VENTILATION, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA FOR PROTECTION
AGAINST MATERIALS IN SECTION II. WHEN SANDING OR ABRAIDING THE
DRIED FILM, WEAR A DUST/MIST RESPIRATOR APPROVED BY NIOSH/MSHA FOR
DUST WHICH MAY BE GENERATED FROM THIS PRODUCT.
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF THE
EXPOSURE TO MATERIALS IN SECTION II IS MAINTAIN BELOW APPLICABLE
EXPOSURE LIMITS.
Protective Gloves:WEAR GLOVES WHICH ARE RECOMMENDED BY GLOVE SUPPLIER.
Eye Protection:WEAR SAFETY SPECTACLES WITH UNPERFORATED SIDESHIELDS.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:=105.6C, 222.F
B.P. Text:222-395 F, 105-201 C
Vapor Density:> AIR
VOC Pounds/Gallon:330
VOC Grams/Liter:2.75
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:39

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE

Disposal

Waste Disposal Methods:WASTE FROM THIS PRODUCT MAY BE HAZARDOUS AS
DEFINES UNDER THE RESOURCE CONSERVATION AND RECOVERY ACT (RCRA) 40
CFR 261. WASTE MUST BE TESTED WITH FOR IGNITABILITY TO DETERMINE
THE APPLICABLE EPA HAZA RDOUS WASTE NUMBERS. INCINERATE IN
APPROVED FACILITY. DO NOT INCINERATE CLOSED CONTAINER. DISPOSE O F
IN ACCORDANCE WITH FEDERAL REGULATIONS.

Regulatory

SARA Title III Information:SARA 313 (40 CFR 372.65C0 SUPPLIER
NOTIFICATION 108-88-3 TOLUENE 1% 95-63-6 1,2,4-TRIMETHYLBEZENE 4%
COBALT COMPOUND 0.2%
Federal Regulatory Information:TSCA CERTIFICATION ALL CHEMICALS IN THIS
PRODUCT ARE LISTED, OR ARE EXEMPT FROM LISTING, ON THE TSCA
INVENTORY.
State Regulatory Information:CALIFORNIA PROPOSITION 65: WARNING: THIS
PRODUCT CONTAINS CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.